38
Name
:
This text field may be used to rename each unit or to reflect the organization who owns the unit.
Location
: Used to describe the location of the device. For example: Northeast corner of 1
st
and Main.
Cabinet Information
: Used to describe the enclosure and/or the equipment that may reside inside the enclosure.
Timezone
: This configuration item is used to set the time offset from UTC time. It is also used to set the time offset in
the event that the Smart Tracker is not able to connect with a NTP server to automatically update the date
and time. Select the timezone that most accurately depicts the location of the unit.
NTP Server
: Each Smart Tracker must be able to automatically update its Device Time using an available NTP
server. Enter the IP address of an accessible NTP server in this text box. Each unit will use this address
upon restart and periodically to maintain accurate device time.
External Sensors
: When enabled, the Summary page will display two additional parameters, the external temperature
and humidity. This is an optional feature and will not display the external values unless the fea-
ture is enabled and an external temperature and humidity sensor is in use.