11
Section 5: Startup
and
Operation
The Smart Tracker is ready to be placed into operation after it has been installed in its rack or enclosure and all input
and output connections have been made. Ensure that AC input power is available to the Smart Tracker receptacle then
perform the following steps in sequence. When started, the Smart Tracker will go through a 45 second initialization
period to restore previously stored states of outlets or relays.
CAUTION
The following steps in the startup procedure MUST be performed exactly as presented; otherwise,
permanent damage to the Smart Tracker may result. Observe the LED indicators and the LCD as a guide
when performing the startup procedure.
1.
Verify that all connections and initial wiring is complete, as previously outlined and described.
2.
Operate the utility AC circuit breaker serving the Smart Tracker to the ON position.
3.
Operate the Input circuit breaker to the RESET or (|) position on the Smart Tracker and the Smart Tracker will
begin its initial start up procedure.
4.
The LCD backlight will illuminate and display operating parameters after a 45 second initialization period.
5.
If outlet states have been previously stored, the respective outlets will automatically turn on as indicated by
their respective LED.
6.
If no outlets are active, press and hold the Enter Button for 5 seconds and release to activate the Hot-Start
feature, which will turn on all 8 outlets.
7.
Verify that equipment that is attached to the Smart Tracker is now powered.
Front Panel LCD Menus
:
Operating parameters of the Smart Tracker are indicated in the various menus available on the Liquid Crystal Display
(LCD) located on the front panel of the Smart Tracker. All menus automatically scroll to show pertinent information.
Multilink
VOLTAGE:
120.00V
Fig. 5-1 LCD and Enter Button
ENTER BUTTON
ENTER