Installation
Ultima Hooklift
01/2020
33
Working order:
13. Remove the test point nipple and install suitable T-connector in the end of hose.
14. Install the test point nipple to T-connector.
15. Install proper LS line hose from T-connector to the pump.
LS line hose preinstalled
at factory.
Remove nipple if JIC T-connector is used.
Leave if BSP T-connector is used.
Use Multilift Service Tool to set the parameter:
XM1.08 (DO) -> Supply voltage
See also separate instructions “ULTIMA LS line configuration.pdf” and
the instruction video in Multilift Product Site.