4.Advanced User Guidebook
(4) Turn the
M
knob to select an object in the left menu. If the source of the selected
waveform is CH1 or CH2, select
AG Output
in the right menu and set the output
channel of the generator. If the source is CH1&CH2, the output channel is not
selectable.
(5) Select
Output
in the right menu.
To output the cloned waveform in the USB memory device
through the generator:
(
MP720106
)
(1) Push
(single-channel) or
(dual-channel) button.
For dual-channel, push
button to set the output channel of the generator.
(2) Select
Arb
in the bottom menu, select
Others
in the right menu, and select
File
Browse
.
(3) select
Memory
in the right menu as
USB
. The instrument lists a directory of the
folders and files on the USB memory device. Select a folder or file using the
M
knob to scroll up and down the list. To enter the current folder, select
Change Dir
in the right menu, select it again to return to the upper directory.
(4) Select the desired ota file, select
Read
in the right menu.
To output the selected waveform through the generator
directly:
(
MP720106
)
(1) Push
Save
button.
(2) Select
Type
in the bottom menu, in the left menu, turn the
M
knob to select
Clone
.
(3) Select
Source
in the bottom menu, select one channel (
CH1
/
CH2)
or two
channels (
CH1&CH2
) in the right menu for Source.
(4) Select
Line
in the bottom menu. Select the cursor and move it to select the
desired waveform.
(5) Select
Clone
in the bottom menu. If the source is CH1 or CH2, select
AG Output
in the right menu and set the output channel of the generator. If the source is
CH1&CH2, the output channel is not selectable.
(6) Select
Clone
in the right menu. The generator will output the waveform between
two cursors.
Move the cursors by gestures
(MP720106 and MP720107)
About the gestures for moving cursors, you can refer to "
Data format description of OTA waveform file
If the source is CH1 or CH2, OTA file consists of two parts: the file header and the
data. If the source is CH1&CH2, OTA file consists of three parts: file header,
CH1data, and CH2 data. The file header represents the parameter of file data, which
is expressed in "parameter name + value".
79
Summary of Contents for MP720105
Page 1: ...i Digital Storage Oscilloscope Model MP720105 MP72016 MP72107...
Page 40: ...4 Advanced User Guidebook Figure 4 2 Rectangle window Figure 4 3 Blackman window 35...
Page 41: ...4 Advanced User Guidebook Figure 4 4 Hanning window Figure 4 5 Kaiser window 36...
Page 68: ...4 Advanced User Guidebook Sine x x interpolation Linear interpolation 63...