Copyright Müller-Elektronik GmbH & Co.KG,
Installation and operating instructions SPRAYDOS (07.2016)
Page - 21 -
6.2.7
"+ 10 %"
, "- 10 %"
,"100 %"
keys
During operation the sprayed rate can be adjusted in degrees of 10% in relation to the pre-set rate by using the keys
and
. An arrow in the display above
shows that a manual adjustment of the spray rate has been
carried out.
By pressing the
key, a manual adjustment of the spray rate by means of the keys
is cancelled out
again. The value entered with the
key is once again set as the pre-set value. The file above
disappears
again.
6.3
Description of the operating data keys
6.3.1
"Start function"
The start function is activated by pressing the keys
, i.e. the memory for the area, spraying fluid and time is
set to "0". Time starts automatically when this key is pressed. This function is to be carried out before each job.
6.3.2
"Area / total area"
This key has a dual function. When the key is pressed for the first time, the area covered since activating the start function
is displayed for 10 seconds. In addition an arrow appears at the bottom of the display above
. If, within 10 seconds the
key is pressed a second time, the total area is displayed. This value is not deleted by the start function. This enables the
total area for a season to be determined. At the beginning of the season the counter is set to "0" by pressing the keys
and
simultaneously.
The area calculation adapts to current conditions. Switched-off boom sections are automatically taken into account.
Measurement is interrupted as soon as the field sprayer is switched off at the main switch.
6.3.3
"Time" key
Operating time since activating the "start function" (6.3.1) is displayed when this key is pressed. An arrow appears
above .
If the computer is switched off, the input of time data is stopped. It restarts once the device has been switched on again.
The clock can also be stopped during operation. After the
key has been pressed, it can be pressed once again to
stop the clock. To restart it press
yet again.
6.3.4
"Spraying fluid l/min" key
Displays the flow meter litres per minute. An arrow appears above
.
6.3.5
"Spraying fluid l and
l" key
This key has a dual function. When the key is pressed for the first time, the quantity spray since activating the start
function (6.3.1 ) is displayed for 10 seconds. In addition an arrow appears at the bottom of the display above
. If, within