952.5-0000010 OM
56
Apart from the fuses, located in the instrument board and shown in fig. 2.21.2 the
on-board circuit of “BELARUS-952.5” tractor has an additional block of fuses 1, located on
the bracket 2 (Figure 2.21.3) of the HLL oil tank body and intended to protect power cir-
cuits of electrical equipment.
1 – fuse block, 2 – bracket; 3 – 80
А
fuse (power to on-board circuit before start-up,
battery charging, positive side to starter relay leads, power to fuel filter heater); 4 – 80
А
fuse (power to heating plugs); 5 – 60
А
fuse (power to instrument board); 6 – 60
А
fuse
(power to instrument board).
Figure 2.21.3 – Fuses, located on HLL oil tank body
Location of the fuse for a battery remote disconnect switch and a stereo-recorder is
shown in figure 2.21.4. Besides a suspended 25A fuse is installed in the circuit of the bat-
tery remote disconnect switch.
2.21.3
Fuse for engine electronic control system
The location of the fuses for the EECS 2 and 4 in the fuse block 3 is shown in fig. 2.21.4
(the fuse block 3 is located above the storage battery 1).
1 – storage battery; 2 – 60A fuse for EECS constant powering (at any position of the
battery disconnect switch); 3 – fuse block; 4 – 80A fuse for EECS powering when the stor-
age battery switch is in turned on position.
Figure 2.21.4 – Installation place of fuse for EECS powering