4.2 Putting the engine into operation after extended out-of-service
periods (>3 months)
Preconditions
☑
Engine is stopped and starting disabled.
☑
MTU Preservation and Represervation Specifications (A001070/..) are available.
Putting the engine into operation (out-of-service period > 3 months)
Item
Measure
Engine
Depreserve (→ MTU Preservation and Represervation Specifications
A001070/..).
Universal shaft
Lubricate (→ Page 213).
Lube oil system
Check engine oil level (→ Page 187).
Fuel prefilter
Fill with fuel (→ Page 179).
Fuel prefilter, pressure
gauge
Align adjustable pointer with position of pressure indicator (→ Page 175).
Fuel system
Vent (→ Page 171).
Raw-water pump (if located
above waterline)
Prime with water (approx. 3 4 l) (→ Page 206).
Coolant circuit
If engine is out of service for more than one year, change engine coolant
(→ Page 201).
Coolant circuit
Check coolant level (→ Page 200).
Coolant circuit
Heat engine coolant with coolant preheating unit.
Engine governor ECU
Check plug-in connections (→ Page 218).
Engine control system
Switch master switch to ON;
Press illuminated pushbutton READY FOR OPERATION (→ Page 105).
LOP
Press illuminated pushbutton LAMP TEST (→ Page 105).
MW15406/17E 2014-05
| Operation | 107
TIM-ID: 0000002215 - 004
Summary of Contents for MW15406/17E
Page 4: ......
Page 20: ...Fuel system covers 20 General Information MW15406 17E 2014 05 TIM ID 0000002178 006...
Page 21: ...MW15406 17E 2014 05 General Information 21 TIM ID 0000002178 006...
Page 22: ...Lube oil system covers 22 General Information MW15406 17E 2014 05 TIM ID 0000002178 006...
Page 23: ...MW15406 17E 2014 05 General Information 23 TIM ID 0000002178 006...