4.9 Waterjet – Flushing from LOP (optional)
Preconditions
☑
LOCAL OPERATION illuminated pushbutton is lit brightly (local operating mode is active).
☑
Vessel is at a standstill and waterjet bucket is below the waterline.
☑
Engine speed is in engagement window.
☑
No external engagement interlock is active.
NOTICE
Waterjet flushing puts excessive strain on the bearings.
Bearing damage!
• Do not flush waterjet for too long.
• Follow instructions of the waterjet manufacturer.
Flushing with reversing gearbox and flushing mode
Item
Measure
LOP
Press FLUSH illuminated pushbutton and keep pressed (→ Page 105).
•
FLUSH pushbutton flashes.
•
Gearbox is engaged astern.
•
After receiving the feedback signal from coupling, the FLUSH pushbut-
ton is illuminated brightly.
LOP
Release FLUSH illuminated pushbutton.
•
FLUSH pushbutton flashes.
•
Gearbox is disengaged (neutral position).
•
Illumination of FLUSH pushbutton is switched off as soon as the feed-
back signal from coupling is received.
114 | Operation | MW15406/17E 2014-05