7.24.2 LOP – Visual inspection
Preconditions
☑
Engine is stopped and starting disabled.
Preparatory steps
1.
If READY FOR OPERATION pushbutton is illuminated brightly, press switch briefly.
Result:
READY FOR OPERATION pushbutton returns to basic brightness.
2.
Switch master power switch to OFF.
3.
Disconnect battery in accordance with battery manufacturer's instructions.
Checking housing and internal
assemblies for secure seating
1.
Open LOP front door.
2.
Check securing screws (1, 3, 4, 7) for firm
seating. Tighten loose threaded connec-
tions.
3.
Check internal assemblies for firm seating,
this applies in particular to printed circuit
board (2) and PIMs (5, 6). Tighten loose
threaded connections.
4.
Close LOP front door.
Checking plug connections
1.
Check all connected cables to verify that
the two securing elements (1) are engaged
on the lugs (2) so that the respective male
connector (3) is held firmly in place in the
socket.
2.
If this is not the case, press the securing el-
ements (1) concerned in the direction of
the arrow until they engage noticeably.
MW15406/17E 2014-05
| Task Description | 223
TIM-ID: 0000008868 - 006
Summary of Contents for MW15406/17E
Page 4: ......
Page 20: ...Fuel system covers 20 General Information MW15406 17E 2014 05 TIM ID 0000002178 006...
Page 21: ...MW15406 17E 2014 05 General Information 21 TIM ID 0000002178 006...
Page 22: ...Lube oil system covers 22 General Information MW15406 17E 2014 05 TIM ID 0000002178 006...
Page 23: ...MW15406 17E 2014 05 General Information 23 TIM ID 0000002178 006...