3.7 Engine data 12V/16V2000Gx6S, 3D, standby current, fuel
stop power (IFN), EPA Nonroad T2 (40CFR89) (provisional)
Legend
CP Ref. value: Continuous power. Continuous driving power under standard conditions
FSP Ref. value: Fuel stop power. Maximum engine power. In some applications, continuous power not pos-
sible (adjustment reserve)
A Design value. Value is required for configuration of an external system (plant)
R Guideline value. Typical average value for information; only conditionally suitable for configuration
L Limit value. Value that must not be undershot (lower limit, min. value) or exceeded (upper limit, max.
value); not suitable for configuration
N Value not yet defined. Value has not yet been, or will not be, named
- Not applicable. Module not relevant to this product type
X Applicable. Module relevant to this product type
> Actual value must be higher than specified value.
< Actual value must be lower than specified value.
* Value not sufficiently guaranteed (tol/- 10%).
** Value not sufficiently guaranteed (tol/- 5%).
ID
Product type
Application
Engine speed
Listed per-
formance
1
12V2000G76S Power generation
3D standby current,
fuel stop power (IFN)
1800 rpm
60 Hz
890 kW
1193 bhp
Ref. 25 °C/45 °C; Wa-
ter charge air cooling
(external)
EPA Nonroad T2
(40CFR89)
EPA Nonroad T2 Comp
(40CFR89)
2
12V2000G86S Power generation
3D standby current,
fuel stop power (IFN)
1800 rpm
60 Hz
987 kW
1323 bhp
Ref. 25 °C/45 °C; Wa-
ter charge air cooling
(external)
EPA Nonroad T2
(40CFR89)
EPA Nonroad T2 Comp
(40CFR89)
3
16V2000G76S Power generation
3D standby current,
fuel stop power (IFN)
1800 rpm
60 Hz
1097 kW
1471 bhp
Ref. 25 °C/45 °C; Wa-
ter charge air cooling
(external)
EPA Nonroad T2
(40CFR89)
EPA Nonroad T2 Comp
(40CFR89)
4
16V2000G86S Power generation
3D standby current,
fuel stop power (IFN)
1800 rpm
60 Hz
1371 kW
1837 bhp
Ref. 25 °C/45 °C; Wa-
ter charge air cooling
(external)
EPA Nonroad T2
(40CFR89)
EPA Nonroad T2 Comp
(40CFR89)
44 | Technical Data | MS15054/00E 2015-09
TIM-ID: 0000065010 - 001