4.5 Stopping the engine in manual mode
Preconditions
☑
Engine is not under load.
☑
Engine is running in manual mode.
NOTICE
Stopping the engine in full load operation causes extreme thermal and mechanical stress to the
engine.
Danger of component damage due to overheating!
• Before stopping the engine, operate it in idle mode until the motor temperatures cool off and
constant values are displayed.
Preparation
Item
Measure
Engine
Operate engine at idling speed for approx. 5 minutes.
Stopping the engine
Item
Measure
Switch cabinet, operator
station etc. (depending on
manufacturer)
Press the stop key (see plant documentation).
•
Automatic stopping sequence is executed.