347 – AL Open Load Cylinder A7
ZKP-Number: 1.8004.546
Injector wiring fault, cylinder A7
Yellow alarm - misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder A7.
1. Check injector wiring for disruption.
2. Rule out any disruption in injector solenoid valve, replace
injector if required (→ Page 125).
3. Fault is corrected after every working cycle.
4. Contact Service.
348 – AL Open Load Cylinder A8
ZKP-Number: 1.8004.547
Injector wiring fault, cylinder A8
Yellow alarm - misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder A8.
1. Check injector wiring for disruption.
2. Rule out any disruption in injector solenoid valve, replace
injector if required (→ Page 125).
3. Fault is corrected after every working cycle.
4. Contact Service.
349 – AL Open Load Cylinder A9
ZKP-Number: 1.8004.548
Injector wiring fault, cylinder A9
Yellow alarm - misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder A9.
1. Check injector wiring for disruption.
2. Rule out any disruption in injector solenoid valve, replace
injector if required (→ Page 125).
3. Fault is corrected after every working cycle.
4. Contact Service.
350 – AL Open Load Cylinder A10
ZKP-Number: 1.8004.549
Injector wiring fault, cylinder A10
Yellow alarm - misfiring
Cause
Corrective action
Disruption fault in injector
wiring, cylinder A10.
1. Check injector wiring for disruption.
2. Rule out any disruption in injector solenoid valve, replace
injector if required (→ Page 125).
3. Fault is corrected after every working cycle.
4. Contact Service.
74 | Troubleshooting | MS150120/00E 2014-11
TIM-ID: 0000029153 - 008