414 – HI Water Level Fuel Prefilter
ZKP-Number: 2.0156.931
Water level in fuel prefilter too high (limit value 1)
Yellow alarm - warning
Cause
Corrective action
Water content in fuel too high.
Water ingress in fuel tank.
u
Drain fuel prefilter.
415 – LO P-Coolant Intercooler
ZKP-Number: 2.0107.921
Coolant pressure in intercooler too low (limit 1)
Yellow alarm - warning
Cause
Corrective action
Leak in coolant circuit.
u
Top up charge-air coolant (→ Page 185).
416 – SS P-Coolant Intercooler
ZKP-Number: 2.0107.922
Coolant pressure in intercooler too low (limit 2)
Red alarm - engine shutdown
Cause
Corrective action
Leak in coolant circuit.
u
Top up charge-air coolant (→ Page 185).
417 – SD Level Water Fuel Prefilter
ZKP-Number: 1.8004.594
Fuel prefilter water level sensor signal error
Yellow alarm - warning
Cause
Corrective action
Water level sensor of fuel
prefilter is faulty.
Short circuit or wire break.
1. Check sensor and wiring, replace as necessary (→ Page 194).
2. Contact Service.
438 – LO P-Fuel 2 (Common Rail)
ZKP-Number: 2.0116.921
Rail pressure > set value
Yellow alarm - DBR fuel limitation
Cause
Corrective action
HP fuel control block faulty or
leakage in HP fuel system.
u
Contact Service.