514 – Flash memory write error
ZKP-Number: 1.8004.611
Value was not transferred to flash memory
Cause
Corrective action
Flash memory faulty.
u
Contact Service.
515 – AL Starter Not Engaged
ZKP-Number: 2.1090.926
Yellow alarm – start termination possible
Cause
Corrective action
Starter on POM could not be
engaged.
1. Repeated start attempt.
2. Check POM, starter and wiring (→ Page 194).
3. Contact Service.
519 – Oil level calibration error
ZKP-Number: 1.0158.921
Error writing calibration value into flash or SD of level sensor.
Yellow alarm - warning
Cause
Corrective action
Oil level sensor or wiring faulty.
1. Check sensor and wiring, replace as necessary (→ Page 194).
2. Contact Service.
536 – AL Wiring PWM_CM1
ZKP-Number: 1.1041.921
Wiring problem at PWM_CM1 channel
Yellow alarm - warning
Cause
Corrective action
Cable break or short circuit on
channel PWM_CM1.
1. Check wiring to connected device or check connected device
itself (actuator/sensor) and replace if necessary (→ Page 194).
2. Contact Service.
549 – AL Voltage interruption
ZKP-Number: 2.7001.952
Alarm from the emergency stop counter function
Yellow alarm - warning
Cause
Corrective action
Engine governor operating
voltage disconnected with
engine still running. This may
result in overpressure in the
high-pressure system, which can
damage the engine.
u
Instruct operators to switch off the power supply only once the
engine has come to a standstill.
MS150120/00E 2014-11
| Troubleshooting | 91
TIM-ID: 0000029153 - 008