Installing NOx sensor
Note:
Note the following:
• If the sensor (3) was subjected to shock
or impact load, it is considered to be de-
fective and may not be used.
• Always replace NOx sensor (3) together
with control unit (1).
1.
Install control unit (1) at the eyelets.
2.
Remove protective cap on thread of sen-
sor (3) only just before installation.
Note:
Do not wipe off the thread lubricant applied
by the manufacturer.
3.
Coat sensor (3) thread with specified as-
sembly compound as required.
4.
Screw in sensor (3) by hand.
5.
Tighten nut (3) with torque wrench to specified tightening torque.
Name
Size
Type
Lubricant
Value/Standard
Nut
M20 x 1.5 Tightening torque
(Assembly compound
(Molykote P 37))
50 Nm ±10 Nm
6.
Fit male connector (2) and latch it.
MS150120/00E 2014-11
| Task Description | 201
TIM-ID: 0000025205 - 011