2.5.2 16V^4000 M53 engine data
Explanation:
DL Referenced value: Continuous power
BL Referenced value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value up to which the engine can be operated without changes, e.g. of load setting.
N Not defined value
- Not applicable
X Applicable
Engine-mounted heat
exchanger
Remote heat ex-
changer
Application group
1A
1A
1A
1A
Intake air temperature
°C
25
45
25
45
Charge-air coolant temperature
°C
-
-
-
-
Raw water inlet temperature
°C
25
32
25
32
Air pressure
mbar
1000
1000
1000
1000
Site altitude above sea level
m
100
100
100
100
POWER DATA (power is net power to ISO 3046)
Engine-mounted heat
exchanger
Remote heat ex-
changer
Rated engine speed
A rpm
1800
1800
1800
1800
Fuel stop power to ISO 3046
A kW
1840
1840
1840
1840
PERIPHERAL CONDITIONS (for maximum power)
Engine-mounted heat
exchanger
Remote heat ex-
changer
Intake air depression (new filter)
A mbar
15
15
15
15
Intake air depression, max.
L
mbar
30
30
30
30
TYPE-RELATED DATA (basic design)
Engine-mounted heat
exchanger
Remote heat ex-
changer
Cylinder arrangement: V-angle
degrees
(°)
90
90
90
90
Bore
mm
170
170
170
170
Stroke
mm
210
210
210
210
Displacement per cylinder
liters
4.77
4.77
4.77
4.77
Total displacement
liters
76.3
76.3
76.3
76.3
Number of intake valves per cylinder
2
2
2
2
Number of exhaust valves per cylinder
2
2
2
2
76 | Product Summary | MS150035/01E 2013-11