2.5 Technical Data
2.5.1 12V 4000 M53 engine data
Explanation:
DL Referenced value: Continuous power
BL Referenced value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value up to which the engine can be operated without changes, e.g. of load setting.
N Not defined value
- Not applicable
X Applicable
Engine-mounted heat
exchanger
Remote heat ex-
changer
Application group
1A
1A
1A
1A
Intake air temperature
°C
25
45
25
45
Charge-air coolant temperature
°C
-
-
-
-
Raw water inlet temperature
°C
25
32
25
32
Air pressure
mbar
1000
1000
1000
1000
Site altitude above sea level
m
100
100
100
100
POWER DATA (power is net power to ISO 3046)
Engine-mounted heat
exchanger
Remote heat ex-
changer
Rated engine speed
A rpm
1800
1800
1800
1800
Fuel stop power to ISO 3046
A kW
1380
1380
1380
1380
PERIPHERAL CONDITIONS (for maximum power)
Engine-mounted heat
exchanger
Remote heat ex-
changer
Intake air depression (new filter)
A mbar
15
15
15
15
Intake air depression, max.
L
mbar
30
30
30
30
TYPE-RELATED DATA (basic design)
Engine-mounted heat
exchanger
Remote heat ex-
changer
Cylinder arrangement: V-angle
degrees
(°)
90
90
90
90
Bore
mm
170
170
170
170
Stroke
mm
210
210
210
210
Displacement per cylinder
liters
4.77
4.77
4.77
4.77
Total displacement
liters
57.2
57.2
57.2
57.2
72 | Product Summary | MS150035/01E 2013-11