2.5.7 Engine data 16V 4000 M43S, IMO Tier II, EPA Tier 2
Explanation:
DL Reference value: Continuous power (CP)
BL Reference value: Fuel stop power (FSP)
A Design value
G Guaranteed value
R Guideline value
L Limit value up to which the engine can be operated without change, e.g. of power setting.
N Not yet defined value
- Not applicable
X Applicable
Heat exchanger
engine-mounted
Heat exchanger
remote
Application group
3B
3B
3B
3B
Intake air temperature
°C
25
45
25
45
Charge-air coolant temperature
°C
--
--
--
--
Raw water inlet temperature
°C
25
32
25
32
Barometric pressure
mbar
1000
1000
1000
1000
Site altitude above sea level
m
100
100
100
100
POWER-RELATED DATA (power ratings are net brake power as per ISO 3046)
Heat exchanger
engine-mounted
Heat exchanger
remote
Rated engine speed
A
rpm
1800
1800
1800
1800
Continuous power ISO 3046 (10% over-
load capability) (design power DIN 6280,
ISO 8528)
A
kW
2240
2240
2240
2240
GENERAL CONDITIONS (for maximum power)
Heat exchanger
engine-mounted
Heat exchanger
remote
Intake depression (new filter)
A
mbar
15
15
15
15
Intake depression, max.
L
mbar
30
30
30
30
MODEL-RELATED DATA (basic design)
Heat exchanger
engine-mounted
Heat exchanger
remote
Cylinder arrangement: V angle
Degrees
(°)
90
90
90
90
Bore
mm
170
170
170
170
Stroke
mm
210
210
210
210
Cylinder displacement
Liters
4.77
4.77
4.77
4.77
Total displacement
Liters
76.3
76.3
76.3
76.3
Inlet valves per cylinder
2
2
2
2
Exhaust valves per cylinder
2
2
2
2
MS150069/02E 2014-03