Final steps – Vertical air intake
1.
Install compressor casing (2).
2.
Tighten screws (1) to specified torque using a torque wrench.
Name
Size
Type
Lubricant
Value/Standard
Screw
Tightening torque
(Engine oil)
20 Nm + 2.5 Nm
3.
Install coolant ventilation line and coolant lines on compressor housing.
4.
Install intake housing (3) with actuating cyl-
inder (2).
5.
Align clamp (1) and tighten to specified torque using a torque wrench.
Name
Size
Type
Lubricant
Value/Standard
Clamp
Tightening torque
15 Nm + 2 Nm
206 | Task Description | MS150069/02E 2014-03
TIM-ID: 0000018629 - 006