Maintenance
Landmark™ Test System Operation
119
Calendar Time using 8 hour
Running Time rate per day
Daily Weekly Biweekly
Annually
Running Time-Hours
8
40
80
500
1000 1,500 2,000
Valve Balance check displacement
control
MTS MTS MTS
MTS
Valve Dither Response
MTS MTS MTS
MTS
Verify High/Low Velocity Switch Light
on High
MTS MTS MTS
MTS
Verify Low Velocity Indicates
Program Interlock
MTS MTS MTS
MTS
Grips
Cursory Check of Grips/Grip Control
MTS MTS MTS
MTS
Grip Supply Connections are Dry
MTS MTS MTS
MTS
Grip Seals are Dry
MTS MTS MTS
MTS
Grip Action is Acceptable
MTS MTS MTS
MTS
Lubricate Grip Inserts
MTS MTS MTS
MTS
Recommended service to be performed at each running time interval noted (continued)
Maintenance Intervals
The following table lists the recommended interval for each of these procedures.
What to Do
When to Do It
Make daily inspections
Before the start of each day’s testing.
Clean the load unit
columns
When the columns become greasy or dirty.
Prevent rust
Depends on the operating environment; more often in humid
environments.
Maintain airmount
pressures
When the load unit sits unevenly.
Perform label inspection At least once a month.
Adjust the hydraulic
locks
When the crosshead sticks or moves jerkily on the column.