21
Temposonics
®
TH CANbus ATEX / IECEx / CEC / NEC / KCs / EAC Ex certified / Japanese approval
Operation Manual
Cable connection (only for versions E and N)
1
Strip the cable for approx. 60 mm (2.36 in.).
2
Install the shrink hose and the ferrules (max. 1.5 mm
2
or
max. 2.5 mm
2
depending on connection).
Step 1: Preparing of cable
Length of shrink hose:
20 mm (0.79 in.)
Length of shrink hose:
40 mm (1.57 in.)
The following two options present how to connect the cable to the
T-Series sensor:
Option 1:
Cable connection via disassembly of connection adapter
Option 2:
Cable connection without disassembly of connection adapter
The figures are examples.
Variations are possible, e.g. different cable colors
NOTICE
The example “Cable connection” is only valid for versions E and N of
the TH sensor. Refer to the corresponding installation requirements
and local regulations, if you like to connect a cable to the TH sensor
versions D and G.
Recommended tools
Electric torque screwdriver
Torque wrench
Slotted screwdriver
Crimping tool
3 mm (0.12 in.),
fastening torque 1.2 Nm
Torque depending on cable
gland
2.0 × 40 mm (0.08 × 1.57 in.)
For ferrules with max. 2.5 mm
2