Output
Interface
Ethernet POWERLINK
Data protocol
POWERLINK V2 according to IEEE 802.3
Measured value
Position, velocity / option: multi-position measurement (2…4 positions)
Measurement parameters
Resolution
1 μm, 2 μm, 5 μm, 10 μm, 50 μm or 100 μm (selectable)
Cycle time
1.0 ms up to 2400 mm stroke length,
2.0 ms up to 4800 mm stroke length,
4.0 ms up to 7620 mm stroke length
Linearity
19
< ±0.02 % F.S. (minimum ±100 µm)
Repeatability
< ±0.001 % F.S. (minimum ±2.5 µm) typical
Hysteresis
< 4 µm typical
Operating conditions
Operating temperature
−40…+75 °C (−40…+167 °F)
Humidity
20
90 % rel. humidity, no condensation
Ingress protection
21
IP30
(IP65 rating only for professional mounted guide pipe and if mating connectors are correctly fitted)
Shock test
100 g (single shock), IEC standard 60068-2-27
Vibration test
5 g (10…150 Hz), IEC standard 60068-2-6 (resonance frequencies excluded)
EMC test
Electromagnetic immunity EN 61000-6-2
Electromagnetic emission EN 61000-6-3
The sensor meets the requirements of the EC directives and is marked with
22
Magnet movement velocity
Any
Design / Material
Sensor electronics housing
Aluminum
Sensor flange
Stainless steel 1.4305 (AISI 303)
Sensor rod
Stainless steel conduct with PTFE coating
Stroke length
150…10,060 mm (6…396 in.)
Mechanical mounting
Mounting position
Any
Mounting instruction
Please consult the technical drawings
Electrical connection
Connection type
2 × M12 female connector (4 pin), 1 × M8 male connector (4 pin)
Operating voltage
23
+24 VDC (−15 / +20 %)
Ripple
≤ 0.28 V
PP
Current consumption
23
110 mA typical
Dielectric strength
500 VDC (DC ground to machine ground)
Polarity protection
Up to −30 VDC
Overvoltage protection
Up to 36 VDC
11.4 Technical data of Temposonics
®
RF
19/
With position magnet # 251 416-2
20/
For professional mounted guide pipe and if mating connectors are correctly fitted
21/
The IP rating is not part of the UL approval
22/
The conformity is fulfilled assumed the wave guide of the sensor is embedded in an EMC-sealed and grounded housing
23/
Power supply must be able to provide current of 1 A for power up process
Temposonics
®
R-Series Powerlink V2
Operation Manual
I 50 I