Temposonics
®
R-Series Powerlink V2
Operation Manual
I 11 I
4.3 Styles and installation of Temposonics
®
RH
Controlling design dimensions are in millimeters and measurements in ( ) are in inches
Fig. 6: Temposonics
®
RH with ring magnet part 1
RH-H / -M / -S / -V
18
(0.71)
Null zone
51
(2.01)
10
(0.4)
Dead zone
63.5 / 66*
(2.5 / 2.6* )
Stroke length
25…7620
(1…300)
Sensor electronics housing
133
(5.24)
A/F 46
Ø
10 ±0.13
(Ø 0.39
±0.01
)
46
(1.81)
53
(2.09)
25
(0.98)
Flange
»M« / »V«
:
M18×1.5-6g
Flange
»S« / »H«
:
¾"-16 UNF-3A
Magnet
* Stroke length > 5000 mm (196.9 in.)
RH-D
Dead zone
63.5 / 66*
(2.5 / 2.6*)
22
(0.87)
15
(0.59)
3
(0.12)
8
(0.31)
Ø 12.8
±0.1
(Ø 0.5
±0.004
)
A/F 46
Ø
10
(Ø 0.39)
Flange:
»D«
M18×1.5-6g
Magnet
* Stroke length > 5000 mm (196.9 in.)
RH-T / -U
Magnet
Flange
»T« / »U«
:
¾"-16 UNF-3A
Null zone
51
(2.01)
7.11
(0.28)
9.65
(0.38)
Dead zone
63.5 / 66*
(2.5 / 2.6* )
Stroke length
25…7620
(1…300)
A/F 44.5
Ø
10 ±0.13
(Ø 0.39
±0.01
)
44.5 (1.75)
51.3
(2.02)
* Stroke length > 5000 mm (196.9 in.)
Ø 25.4 (Ø 1)
RH-R
Dead zone
70 / 72.5*
(2.76 / 2.85*)
3.5
(0.14)
6
(0.24)
M4 thread
A/F 46
Ø
10 ±0.13
(Ø 0.39
±0.01
)
Flange:
»R«
M18×1.5-6g
Magnet
* Stroke length > 5000 mm (196.9 in.)