Color Reference Bar
The Color Reference Bar spans temperatures from 0°F (0°C) to 300°F (160°C) in High Sensitivity
mode and 0°F (0°C) to 1000°F (600°C) in Low Sensitivity mode and provides a temperature ref-
erence for the Temperature Indicator Bar. The scale dynamically changes with a change in sen-
sitivity mode. A green triangle appears over the scale to indicate a sensitivity mode other than
high-sensitivity mode.
-
The scale is also used as a reference for image colorization. The yellow, orange and red seg-
ments of the bar correspond to the temperatures at which colorization is introduced on the
camera.
NOTE: Colorization is introduced at different temperatures depending on whether the camera is
in High or Low Sensitivity mode.
The Color Reference Bar is only visible for "White Hot" imagery.
In High Sensitivity Mode
In Low Sensitivity Mode
When Temperatures are
Objects:
below 291 °F (144 °C)
Are shown as standard gray scale images
between 291 °F (144 °C) and 302 °F (150 °C)
Turn
yellow
, starting with light
shades changing to darker shades
between 302 °F (150 °C) and 311 °F (155 °C)
Turn
orange
, starting with light
shades changing to darker shades
over 311°F (155 °C)
Turn
red
, starting with light shades
changing to darker shades
When Temperatures are:
Objects:
between 1000 °F (540 °C) and 1047 °F (564 °C) Turn
yellow
, starting with light
shades changing to darker shades
between 1047 °F (564 °C) and 1090 °F (588 °C) Turn
orange
, starting with light
shades changing to darker shades
over 1090 °F (588 °C)
Turn
red
, starting with light shades
changing to darker shades