EVOLUTION 6000 Thermal Imaging Camera
22
Use
MSA
US
Fig. 8
Additional EVOLUTION 6000+ TIC and 6000 X TIC on-screen indicators
3.6
Accessing the NFPA Plus Features
Thermal imaging cameras compliant with
NFPA 1801, Standard for Thermal Imaging Cameras in
the Fire Service
, require a deliberate action to access all camera features beyond those described
as NFPA Basic functions.
Non-NFPA-compliant cameras (reference the approval label on the underside of the camera) do
not require a special sequence. All features are available at camera turn-ON.
Once the camera is turned ON, push and hold either the ZOOM or the PALETTE button for three
seconds until the Plus Mode Indicator appears on the screen (
Fig. 8).
-
All Plus features are now available.
-
All applicable indicators appear on screen.
To return to the Basic mode:
(1)
Briefly push and release the ON/OFF button.
or
(2)
Turn the camera OFF and back ON again.
The Plus mode indicator and any applicable feature indicators turn OFF.
1
Plus Mode indicator
4
Color Palette indicator (Plus Feature)
2
Zoom Level indicator (Plus Feature)
5
Range Finder
3
Compass (Plus Feature)
5
1
2
3
4
WARNING
Do not attempt to use NFPA Plus features without adequate training. Without proper training,
some features may lead to firefighter disorientation and unexpected camera operation.