9 Technical data
80
BA5831400-00 EN
Dimensions and weight
Compact housing
Ø 173 mm [Ø 6.81"]; depth 98 mm [3.86"]
Compact RM housing
Ø173 mm [Ø6.81"]; depth 71 mm [2.80"]
Weight
Approx. 2.5 kg (for 6 m capillary line)
Analog sensor (TT version/
optional)
Sensor
Pressure measurement cell
Supply voltage
DC: 12...30 V unregulated, max. 10% residual rip-
ple, protected against polarity reversal
Output signal
4…20 mA; 2-conductor wiring
Max. load resistance
e.g. 750 Ω at U
b
= 24V DC
Repetition accuracy
≤ ±0.1% from the end value
Maximum load resistance
1.5 Pt
0.7 Pt
Arial 9 Pt
10
20
30
40
50
0.1
0.2
0.5
1
2
5
10
20
A
U
I
750
150
50
10
25
15
20
30
5
12
24
R [Ω]
L
B
U [V]
Operating range
R [Ω]
L
=
U
B
-9 [V]
20 [mA]
Figure 61: Maximum load resistance
Connection terminals
Connection terminals
1.5...2.5 mm
2
, 16...12 AWG (rigid or flexible)