![Moxa Technologies VPort D361 User Manual Download Page 50](http://html.mh-extra.com/html/moxa-technologies/vport-d361/vport-d361_user-manual_1842268050.webp)
VPort D361
System Configuration
4-22
Schedule
A schedule is provided to set event alarms for daily security applications.
Weekly Schedule
Setting
Description
Default
Event Alarms are active
all the time
Select the option “Event Alarms are active all the time”
Event Alarms are
active all the time
Event Alarms are on a
weekly schedule
Select to operate event alarms on a weekly schedule.
NOTE
Either Event Alarms are active all the time or Event Alarms are active based on weekly schedule must
be selected, or the applications described in the following sections will not work properly.
Setting
Description
Default
□
Sun
□
Mon
□
Tue
□
Wed
□
Thu
□
Fri
□
Sat
Select the days of the week for the event alarms’ schedule.
None
Begin 00:00
Set the beginning time of event alarm.
00:00
Duration 00:00
Setup the time period of event alarm being activated.
00:00
Digital Input
Two digital inputs are provided by the VPort D361 for linking with alarm detection devices, such as sensors.
Setting
Description
Default
Enable digit input alarm Enable or disable the digit input alarm.
Disable
Trigger Conditions
Setting
Description
Default
High
The DI is always in the “High” state after an alarm is detected. Disabled
Low
The DI is always in the “Low” state after an alarm is detected. Enabled
Rising
The DI goes from state “Low” to state “High” and then back to
state “Low” when an alarm is detected.
Disabled
Falling
The DI goes from state “High” to state “Low” and then back to
state “High” when an alarm is detected.
Disabled