![Moxa Technologies VPort D361 User Manual Download Page 42](http://html.mh-extra.com/html/moxa-technologies/vport-d361/vport-d361_user-manual_1842268042.webp)
VPort D361
System Configuration
4-14
Video Source
Video Source List
A maximum of 64 video sources can be added to the VPort D361’s video source list. The Administrator can
configure the video source operation settings on this page.
Video Source Switch Mode
Setting
Description
Default
Enable DI change
Enable the video source change via the DIs.
DI 1 selects UP (from 1 to 2)
DI 2 selects DOWN (from 2 to 1)
Disabled
Auto Scan
Enable the video source change by automatically scanning all
the video sources in the list
Disabled
Interval
Time interval for switching the current video source to the next
video source in auto scan mode
30 sec
(10-999)
Alarm Trigger Interval Time interval for doing the video source switch once the next
alarm is triggered.
3 sec
(3-999)
NOTE
The Alarm Trigger Interval is used for the alarm buffer, and is used to prevent several alarms from being
triggered at the same time. Otherwise, there could be a conflict in the operation of the video source switch. For
this reason, you must set up a time interval between the 2 alarms. The alarms triggered during this time
interval will be ignored.