Limit (only active for MAC Address Sticky)
Setting
Description
Factory Default
1 to 1024
The maximum number of learned MAC addresses allowed for
that port.
1
Violation Port Disable (only active for MAC Address Sticky)
Setting
Description
Factory Default
Disable
When the port limit is reached and the port receives a packet
with an unknown MAC address (unlearned by the port), the
packet will be discarded.
Disable
Enable
When the port limit is reached and the port receives a packet
with an unknown MAC address (unlearned by the port), the
port will be disabled.
Static Port Lock
Port Number
Setting
Description
Factory Default
Port Number
Associates the static address to a dedicated port
None
VID
Setting
Description
Factory Default
VLAN ID
Associates the static address to a dedicated VLAN on the port None