Moxa Managed Ethernet Switch (UI_2.0_FW_5.x) User Manual
117
NOTE
The following events will be recorded into the Moxa switch’s Event Log Table:
•
Cold start
•
Warm start
•
Configuration change activated
•
Power 1/2 transition (Off ( On), Power 1/2 transition (On ( Off))
•
Authentication fail
•
Topology changed
•
Master setting is mismatched
•
Port traffic overload
•
dot1x Auth Fail
•
Port link off/on
Tracking
The tracking function can monitor the status of a port, the status of an interface, and the availability of a
host by pinging it. The status of tracking (up/down) is the result of the monitored target. The tracking
function can bind a tracking entry and perform a specific action according to the status of the tracking
entry.
Tracking Function
Enable Tracking Function
Setting
Description
Factory Default
Enable
Select the Enable checkbox to enable the Tracking Function.
Disabled
Disable
Deselect the Enable checkbox to disable the Tracking
Function.
Interface Tracking
Monitor a port interface. If the status of interface tracking entry is down, it means that the port interface is
down. Alternatively, the status of the interface tracking entry is up.