Moxa Managed Ethernet Switch (UI_2.0_FW_5.x) User Manual
27
System Events
Description
RSTP Root Changed
If the RSTP root has changed
RSTP Topo. Changed
If any Rapid Spanning Tree Protocol switches have changed their position
(applies only to the root of the tree)
Turbo Ring Break
Turbo Ring path is disconnected
DI1 (On
Off)
Digital Input 1 is triggered by an on to off transition
DI1 (Off
On)
Digital Input 1 is triggered by an off to on transition
ABC-02 Status
Detects if the ABC-02-USB-T is connected or disconnected to the switch
when the ABC-02-USB-T automatically imports/exports/backs-up the
configuration
Rate Limited On (Disable Port)
When the port is disabled due to the ingress throughput exceeding the
configured rate limit.
Rate Limited Off (Disable Port)
The port disable function is off because it exceeds the traffic duration or
the user changes “Port Disable” mode to “Drop Packet” mode.
Port Looping
Port looping event is triggered
LLDP Table Change
Nearly connected devices are changed and shown in the LLDP table
Login Failure Lockout
The attempt to log in exceeds the threshold
Account Info Changed
The account information has been changed
Configuration is Imported
When the configuration is successfully imported
SSL Certification is Imported
When SSL Certification is successfully imported
Fiber Check Warning*
If the corresponding value of the fiber port status exceeds the threshold
defined by the Fiber Check function
MAC Sticky Violation Port Disable Any port with MAC sticky function is disabled because of a rule violation
*The Fiber Check Warning event is only supported by EDS-P506E-4PoE, EDS-510E, EDS-518E,
EDS 528E, and EDS-G500E Series.
Four response actions are available on the EDS E series when events are triggered.
Action
Description
Trap
The EDS E series will send a notification to the trap server when an event is triggered.
The EDS E series will send a notification to the email server defined in the Email Setting.
Syslog
The EDS E series will record a syslog to syslog server defined in Syslog Server Setting.
Relay
The EDS E series supports digital inputs to integrate sensors. When an event is triggered,
the device will automate alarms through the relay output.
Severity
Severity
Description
Emergency
System is unusable
Alert
Action must be taken immediately
Critical
Critical conditions
Error
Error conditions
Warning
Warning conditions
Notice
Normal but significant condition
Information
Informational messages
Debug
Debug-level messages