![Moxa Technologies EDS-510E Series User Manual Download Page 118](http://html1.mh-extra.com/html/moxa-technologies/eds-510e-series/eds-510e-series_user-manual_1842400118.webp)
Moxa Managed Ethernet Switch (UI_2.0_FW_5.x) User Manual
118
Enable Interface Tracking
Setting
Description
Factory Default
Enable
Select the Enable checkbox to enable the interface tracking
entry.
Enabled
Disable
Deselect the Enable checkbox to disable the interface tracking
entry.
Tracking ID
Setting
Description
Factory Default
1 to 64
The tracking ID of the interface tracking entry.
No
NOTE
The tracking ID has to be unique.
Interface Type
Setting
Description
Factory Default
Port
The type of the monitored interface.
Port
NOTE
The port cannot be modified if the configuration is applied.
Port / VID
Setting
Description
Factory Default
All the existing ports /
All the existing layer 3
interfaces
The monitored interface.
The first port
Interval (ms)
Setting
Description
Factory Default
100 to 100,000 ms
The interval that the interface tracking checks the status of
the monitored port or layer 3 interface.
1,000 ms
Up Delay (ms)
Setting
Description
Factory Default
0 to 100,000 ms
The threshold that the status of interface tracking changes
from down to up when the status of the monitored port or
layer 3 interface is greater than or equal to the up delay.
1,000 ms
If the
Up Delay
is 0 ms, then the status of the interface tracking changes immediately when the status of a
monitored interface changes from down to up. On the other hand, if the Up Delay is 100,000 ms, then the
status of the interface tracking entry would never change from down to up.
Down Delay (ms)
Setting
Description
Factory Default
0 to 100,000 ms
The threshold that the status of interface tracking changes
from up to down when the status of the monitored port or
layer 3 interface is down greater than or equal to the down
delay.
1,000 ms
If the
Down Delay
is 0 ms, then the status of interface tracking changes immediately when the status of a
monitored interface changes from up to down. On the other hand, if the
Down Delay
is 100,000 ms, then
the status of the interface tracking entry never changes from up to down.