Auto backup of event log to prevent overwrite
This function is designed to maintain a long-term record of the switch’s log files. Moxa Ethernet switches are
capable of saving 1000 event log entries. When the 1000-entry storage limit is reached, the switch will
delete the oldest saved event log. The ABC-02 can be used to back up these event logs. When the number
of switch log entries reaches 1000, the ABC-02 will save the oldest 100 entries from the switch.
Enable the
Auto backup of event log to prevent overwrite
, and then click
Apply
. After that, when the
ABC-02 is plugged into the switch, the event logs will always be saved to the ABC-02 automatically when
the number of switch log entries reaches 1000. Each backup action saves the oldest 100 logs to the ABC-02
in one file, with the filename generated by the current system time as
MMDDHHmm.ini
. The file is saved
to the
His_log
folder.
NOTE
MM=month, DD=day, HH=hour, mm=minutes, from the system time.
The log file includes the following information:
Index
An event index assigned to identify the event sequence.
Bootup Number
This field shows how many times the Moxa switch has been rebooted or cold started.
Date
The date is updated based on how the current date is set on the System Settings page.
Time
The time is updated based on how the current time is set on the System Settings page.
System Startup
Time
The system startup time related to this event.
Event
Events that have occurred.
Switch Reset Button
The Moxa switch reset button can be used to quickly reset the switch’s configuration, and save the current
configuration and log files to the ABC-02. Press the Reset button on top of the EDS switch to back up the
current system configuration files and event logs to the ABC-02.
NOTE
DO NOT remove the ABC-02 when performing an upgrade, backup, or restore.
Turbo Ring DIP Switch
The
Turbo Ring DIP Switch
page allows users to disable the 4th DIP switch located on the EDS’s outer
casing. The default is enabled with Turbo Ring v2 protocol. Once the user changes the 4th hardware DIP
switch configuration to
ON
, the switch will start to initiate the Turbo Ring redundancy protocol based on the
configuration. The detailed description is given below: