AirWorks AWK-3131A
Web Console Configuration
3-59
DI and Power Status
The status of power inputs and digital inputs is shown on this web page. The status will refresh every 5
seconds if the Auto refresh box is checked.
AeroLink Protection Status (For Client/Slave Mode Only)
After you have enabled AeroLink Protection in the Advanced WLAN Setup panel, the current state of the
AeroLink Protection is displayed here for easy diagnosis.
A member of the AeroLink Protection group can take one of the following seven states:
•
Initiation State (Init): Initiates the AeroLink Protection Protocol
•
Discovering State (Discover): Discovers other AeroLink Protection members for further negotiation
•
Idle State (Idle): Internal protocol checkpoint
•
Negotiation State (Nego): Negotiates with other AeroLink Protection members and elects an Active
node.
•
Backup State (Backup): After negotiation, this node is assigned as a Backup node. All traffic will go
through the Active node instead.
NOTE
When a node is in Backup state, the STATE LED will be blinking.
•
Active State (Active): After negotiation, this node is assigned as Active node, which means that all
traffic will go through this node.
•
Role Change State (Change): If the Active node is no longer capable of data transmission via the
WLAN, it will turn into Change State to trigger the re-negotiation of the Active node from the Backup
nodes.
AeroLink Protection function can adopt one of the following detection methods:
•
SNR: Checks the Signal-Noise Ratio (SNR) of the associated client
•
Signal Strength: Checks the Signal Strength of the associated client
•
Disconnection: Checks for disconnection