AWK-3131A-M12-RCC
Web Console Configuration
3-7
Gateway
Setting
Description
Factory Default
AWK-3131A-M12-RCC’s
default gateway
The IP address of the router that connects the LAN to an
outside network.
None
Primary/ Secondary DNS server
Setting
Description
Factory Default
IP address of the
Primary/Secondary
DNS server
The IP address of the DNS Server used by your network. After
entering the DNS Server’s IP address, you can input the
AWK-3131A-M12-RCC’s URL (e.g., http://ap11.abc.com) in
your browser’s address field instead of entering the IP address.
The Secondary DNS server will be used if the Primary DNS
server fails to connect.
None
Time Settings
The AWK-3131A-M12-RCC has a time calibration function based on information from an NTP server or user
specified Date and Time information. Functions such as Auto warning can add real-time information to the
message.
The Current local time shows the AWK-3131A-M12-RCC’s system time when you open this web page. You
can click on the Set Time button to activate the updated date and time parameters. An “(Updated)” string will
appear to indicate that the change is complete. Local time settings will be immediately activated in the system
without running Save and Restart.
NOTE
The AWK-3131A-M12-RCC has a built-in real time clock (RTC). It is strongly recommended that users update
the Local time for the AWK-3131A-M12-RCC after the initial setup or a long-term shutdown, especially when
the network does not have an Internet connection for accessing the NTP server or there is no NTP server on
the LAN.
Current local time
Setting
Description
Factory Default
User adjustable time
The date and time parameters allow configuration of the local
time, with immediate activation.
Use 24-hour format: yyyy/mm/dd hh:mm:ss
None