AirWorks AWK-3131A
Web Console Configuration
3-47
115200, 230400,
460800, 921600
Data Bits
Setting
Description
Factory Default
5, 6, 7, 8
This field specifies the number of data bits used to encode each
character of data.
8
Stop Bits
Setting
Description
Factory Default
1, 1.5, 2
This field specifies the number of stop bits used for each
character frame.
1
Parity
Setting
Description
Factory Default
None, Odd, Even,
Space, Mark
This field specifies the type of parity bit used for each character
frame.
None
Flow Control
Setting
Description
Factory Default
None, RTS/CTS,
XON/XOFF
This field specifies the type of flow control used by the serial
port.
RTS/CTS
FIFO
Setting
Description
Factory Default
Enable, Disable
This field specifies whether the serial port will use the built-in
FIFO. A 128-byte FIFO is provided to each serial port for both
Tx and Rx directions. To prevent data loss during serial
communication, this should be set to Disable if the attached
serial device does not have a FIFO.
Disable
Interface
Setting
Description
Factory Default
RS-232, RS-422,
RS-485 2-wire,
RS-485 4-wire
This field specifies the type of interface the serial port will use. RS-232
Data Buffering/Log
On the serial port’s
Data Buffering/Log
page, you can enable or disable
Port buffering
and
Serial data
logging
.