AirWorks AWK-3131A
Web Console Configuration
3-61
System log will indicate the link fault pass through events in addition to the original link up/down events.
Link Fault Pass-Through
Setting
Description
Factory Default
Enable
Enables Link Fault Pass-Through
Disable
Disable
Disables Link Fault Pass-Through
NOTE
Auto MAC Cloning cannot be used together with Link Fault Pass Through.
Logs and Notifications
Since industrial-grade devices are often located at the endpoints of a system, these devices will not always
know what is happening elsewhere on the network. This means that these devices, including wireless APs or
clients, must provide system maintainers with real-time alarm messages. Even when system administrators
are out of the control room for an extended period, they can still be informed of the status of devices almost
instantaneously when exceptions occur.
In addition to logging these events, the AWK-1137C supports different approaches to warn engineers
automatically, such as SNMP trap, e-mail, and relay output. It also supports two digital inputs to integrate
sensors into your system to automate alarms by email and relay output.
System Logs
System Log Event Types
Detailed information for grouped events is shown in the following table. Check the box for
Enable logging
to
enable the grouped events. All default values are enabled (checked). The log for system events can be seen in
Status
System Logs
.
System-related events
Event is triggered when…
System warm start
The AWK-1137C is rebooted, such as when its settings are
changed (IP address, subnet mask, etc.).
System cold start
The AWK-1137C is rebooted by power down.
Watchdog triggers reboot
The AWK-1137C is rebooted by watchdog
.
Network-related events
Event is triggered when…
LAN link on
The LAN port is connected to a device or network.
LAN link off
The port is disconnected (e.g., the cable is pulled out, or the
opposing device shuts down).