14
ture and the temperature sensor location may cause a difference between the
actually measured temperature inside the sauna and the heating temperature
set on the control panel amounting up to 5 °C.
Heating Start/Stop
With the system on the POWER control below the display is illuminated
and if the temperature inside the sauna is lower than the setpoint the HEAT
control below the display will illuminate and the heating units will start work-
ing.
If you reduce the temperature setpoint by 2 °C below the temperature inside
the sauna the heaters will stop heating.
The recommended temperature is 50 °C, in low ambient temperature the heat-
ing time is longer.
when the temperature reaches the set value the heaters are switched off and
the control of the HEAT
FUNCTION ON THE CONTROL PANEL will go off. After the heater stop the set
temperature will be kept inside the sauna for some time. When it drops by 2 °C
the heaters will be started again to restore the set temperature.
Reading Lamp Switch Inside Sauna
Press the Inside light button once to switch the lamp on and again to
switch it off.
Roof light switch
Press the roof light switch on the TOP PLATE in front of the front door.
Use this switch again to turn it off.
6
7
8
Sauna Control and Operation