INPUT 1 CONFIG
This parameter defines the switching characteristics of the input “Ctrl. In 1”.
0
ACTIVE LOW
Active at „LOW“ (static)
1
ACTIVE HIGH
Active at „HIGH“ (static)
2
RISING EDGE
Activate at rising edge (dynamic)
3
FALLING EDGE
Activate at falling edge (dynamic)
INPUT 2 ACTION
This parameter defines the function of the input “Ctrl. In 2”.
See parameter INPUT 1 ACTION
INPUT 2 CONFIG
This parameter defines the switching characteristics of the input “Ctrl. In 2”.
See parameter INPUT 1 CONFIG.
INPUT 3 ACTION
This parameter defines the function of the input “Ctrl. In 3”.
See parameter INPUT 1 ACTION.
INPUT 3 CONFIG
This parameter defines the switching characteristics of the input “Ctrl. In 3”.
See parameter INPUT 1 CONFIG.
5.18
Display Menu
Parameter changes become active only after closing the menu selection.
START DISPLAY
This parameter defines the start display after switching on the device.
0 Single
Single-line display
The source must be defined in SOURCE SINGLE
1 Dual
The sources must be defined in SOURCE DUAL TOP / DOWN.
SOURCE SINGLE (Reference source for single-line display)
0
INPUT 1
the reference source is input 1
1
INPUT 2
the reference source is input 2
2
LINKAGE 1 – 2
the reference source is the result of the linking of input1 and input 2
3
INPUT 1 TOTAL
the reference source is input 1 with totalization
4
INPUT 2 TOTAL
the reference source is input 2 with totalization
5
LINKAGE TOTAL
the reference source is the result of the linking of input1 and input 2 with
totalization
6
IO LINK VALUE 1
the reference source is the process data out value 1 sent by the IO-Link master
7
IO LINK VALUE 2
the reference source is the process data out value 2 sent by the IO-Link master
8
MINIMUM VALUE 1
minimum value, the reference source is input 1
9
MAXIMUM VALUE 1 maximum value, he reference source is input 1
10 MINIMUM VALUE 2
minimum value, the reference source is input 2
11 MAXIMUM VALUE 2 maximum value, he reference source is input 2