Ax350_04a_oi_e.doc / May-18
Seite 12 / 54
Wiring of the control-outputs:
3.9
AC Power supply (Option AC)
The unit accepts AC supply from 115 to 230 V at the terminals 24 and 25. The power consumption
depends on the level of the supply voltage with aprox. 3VA and the additional current required at the
auxiliary voltage output.
Devices with option AC can also be supplied with a DC voltage between 18 and 30 VDC at terminals 1
and 2.
3.10
Relay-Output (Option RL)
Two relay outputs with potential-free changeover contacts are available at terminal 27, 28, 29 and 30,
31, 32. Switching conditions can be set in the PRESELECTION MENU. The switching states are
displayed (display with unit and status bar) as K1 and K2.
AC-switching capacity max 250 VAC/max. 3 A / max 750 VA
DC-switching capacity max 150 VDC /max. 2 A / max 50 W
Wiring of the relay outputs: