5.10 Preselection Values
This menu is used to set the preselection values or the switching points.
The preselection values / switching points are always referred to the display value.
This menu is only available for devices with option CO, A0 or RL.
PRESELECTION 1
(Preselection / switching point 1)
-99999999
Smallest value
1000
Default value
+99999999
Highest value
PRESELECTION 2
(Preselection / switching point 2)
-99999999
Smallest value
2000
Default value
+99999999
Highest value
PRESELECTION 3
(Preselection / switching point 3)
-99999999
Smallest value
3000
Default value
+99999999
Highest value
PRESELECTION 4
(Preselection / switching point 4)
-99999999
Smallest value
4000
Default value
+99999999
Highest value
5.11
Preselection 1 Menu
Switching conditions for preselection 1. Output/ relay/ display switches under the following conditions.
This function is only available for devices with option CO, AO or RL.
SOURCE 1
This parameter defines the reference source for PRESELECTION 1
0 INPUT 1
the reference source is input 1
1 INPUT 2
the reference source is input 2
2 LINKAGE 1 – 2
the reference source is the result of the linking of input1 and input 2
3 INPUT 1 TOTAL
the reference source is input 1 with totalization
4 INPUT 2 TOTAL
the reference source is input 2 with totalization
5 LINKAGE TOTAL
the reference source is the result of the linking of input1 and input 2 with
totalization
6 IO LINK VALUE 1
the reference source is the process data out value 1 sent by the IO-Link master
7 IO LINK VALUE 2
the reference source is the process data out value 2 sent by the IO-Link master
8 MINIMUM VALUE 1
minimum value, the reference source is input 1
9 MAXIMUM VALUE 1 maximum value, he reference source is input 1
10 MINIMUM VALUE 2
minimum value, the reference source is input 2
11 MAXIMUM VALUE 2 maximum value, he reference source is input 2