background image

 

QXe Recorder - Installation Instruction 

 
Touch Screen Assembly 

 

 

QXe Recorder 

 

 

This Installation Instruction sheet is intended as a guide for replacing or installing hardware and for setting up 
functionality in the recorder. Refer to the User manual for detailed operational requirements.   
The QXe Recorders are designed for ease of assembly with minimal disturbance to the rest of the unit. If unsure, please 
return the unit to your supplier for repair or upgrade. 
Removing the case and opening the back of the recorder should only be performed under the following circumstances: 
When an item of hardware requires individual replacement. 
When an item of hardware is to be retrospectively fitted. 
In all other instances it is recommended that the complete unit be returned to an authorised agent or service centre. 
For Agency Approved recorders the product needs to be upgraded or repaired by an Authorized Repair facility 

 

 

 WARNING 

HAZARDOUS VOLTAGES  

Disconnect all power to the recorder before removing the case and attempting any maintenance procedures. 

SAFETY TESTS 

Upon completion of service procedures detailed in this manual two basic safety tests should be performed in order to 
ensure continued safe operation of the instrument. 
Earth Resistance; 25 VDC applied between case and protective earth, bonding resistance should be < 0.1 Ohm. 
Insulation Resistance; 500Vdc applied between the earth terminal, and the live and neutral terminal shorted together, 
insulation resistance to be >2.0 MOhm. (Mega Ohm, NOT milli Ohm) 

Failure to comply with these instructions could result in death or serious injury

 

 

 CAUTION 

OBSERVE ANTI-STATIC PRECAUTIONS 

Refer to BS EN61340-5-1: 2001. Basic specification. Protection of electrostatic sensitive devices. 
Full anti-static precautions MUST be observed when in contact with the electronics of your recorder. 

SAVE DATA, SETUPS AND LAYOUTS 

Removal of PCBs and battery back-up will result in the loss of all non-volatile data.  
Ensure all data and set-ups are saved. 

Failure to comply with these instructions may result in product damage.

 

 

43-TV-33-88 iss.2   GLO   Nov 06   UK 

 

Summary of Contents for QXe Recorder

Page 1: ...Disconnect all power to the recorder before removing the case and attempting any maintenance procedures SAFETY TESTS Upon completion of service procedures detailed in this manual two basic safety tests should be performed in order to ensure continued safe operation of the instrument Earth Resistance 25 VDC applied between case and protective earth bonding resistance should be 0 1 Ohm Insulation Re...

Page 2: ... the panel Loosen the mounting clamp screws slide the clamp towards the rear of the recorder and remove the clamps and the recorder Removing the Case and Rear Panel To fit a new Touch Screen assembly the case and back panel must be removed The case and back panel can be removed as a single assembly Remove the 2 screws on each side of the case as shown in Fig 1 below 43 TV 33 88 iss 2 GLO Nov 06 UK...

Page 3: ...4 screws have been removed the complete Front Surround Assembly can be gentle pulled forward to release it from the chassis plates The Front Surround assembly will still be attached by the cables Fig 3 Carefully unplug the inverter lead the display lead the speaker lead and the touch screen lead All leads should be unplugged from the processor board and left attached to the Front Surround assembly...

Page 4: ... the touch screen assembly Remove the 4 self tapping screws as shown in Fig 4 above two at the top of the assembly and one each side at the bottom Once the 4 screws have been removed the touch screen assembly can be separated from the display assembly Care should be taken not to touch the display Fig 5 Touch Screen assembly Display assembly 43 TV 33 88 iss 2 GLO Nov 06 UK 4 ...

Page 5: ...lf tapping screws to complete the assembly of the Front surround Re fitting the Front Surround assembly Fig 6 Display lead Touch Screen lead Inverter lead Speaker lead Offer up the Front Surround assembly and identify the four cables shown in Fig 6 Reconnect the leads to the processor board ensuring that the connectors are inserted with the correct orientation Slide the Front Surround assembly bac...

Page 6: ...the Touch Test option on the recorder This allows you to touch the screen and check a cursor moves to the correct position This can be accessed by entering the Main Menu then Screen then Touch Test If the touch screen needs recalibrating Exit the touch test screen with the finish button the press Calibrate This will take you to the calibration screen Using the stylus touch the screen at the centre...

Reviews: