2.
How to Operate the Front Keys
For setup and other operations the unit uses three front keys which subsequently will be
denominated as follows:
«
ENTER
(Input)
SET
(Setting)
Cmd
(Command)
The functions of the keys are depending on the actual operating state of the unit.
The following three operating states apply:
x
Normal display state
x
Setup state
a.) Basic setup
b.) Operational parameter setup
x
Teach operation
2.1. Normal display state
You can only change over to other operation states while the unit is in the
normal display state.
Change over to
Key operation
Basic setup
Keep EENTER and S
SET down simultaneously for 3 seconds
Operational
parameter setup
Keep EENTER down for 3 seconds.
Teach operation Keep
C
Cmd down for 3 seconds
The Cmd key is only used to execute the Teach procedure with linearization. For more details