IX34208a_e.doc / Aug-09
Page 8 / 40
2.2. Selection and Setting of Parameters
2.2.1.
How to select a parameter
The EENTER key will scroll through the menu. The S
SET key allows to select the corresponding
item and to change the setting or the numeric value. After this, the selection can be stored by
ENTER again, which automatically changes over to the next menu item.
2.2.2.
How to change parameter settings
With numerical entries, at first the lowest digit will blink. When keeping the S
SET key
continuously down, the highlighted digit will scroll in a continuous loop from 0 … 9 , 0 … 9.
After releasing the S
SET key, the actual value will remain and the next digit will be highlighted
(blink). This procedure allows setting of all digits to the desired values. After the most
significant digit has been set, the low order digit will blink again and you can do corrections if
necessary.
With signed parameters, the high order digit will scroll from “0” to "9" (positive) followed by
“-“ and "-1" (negative)
2.2.3.
How to store settings
To store the actual setting, press the EENTER key, which will also automatically scroll forward
the menu.
At any time the unit changes from programming mode to normal display operation, when you
keep the EENTER key down again for at least 3 seconds.
2.2.4.
Time-out function
A “time-out” function will automatically conclude every menu level, when for a break period of
10 seconds no key has been touched. In this case, any changes which have not been confirmed
by EENTER yet would remain unconsidered.