Canopy
T1/E1
Multiplexer
September
2004
T1/E1
Multiplexer
FPGA
Version
3.4
Page
54 of 73
3.2
T1/E1
ALARMS
Each T1/E1 channel has alarms for line code violation (BPV), receive loss of signal
(LOS), and alarm indication signal (AIS) detection.
Follow these steps to display the alarms using the CLI.
Procedure 23: Displaying the alarms using the CLI
Action Steps
Log in
Press Enter.
At the
username
prompt, enter
admin
.
At the password prompt, enter
password
.
View T1/E1 Alarms
Enter
get alarms
.
The system responds displays alarms for all 4 T1/E1 ports, as in the
following example:
Line1:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
Line2:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
Line3:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
Line4:
Line code violation: No
Receive Loss of Signal: No
Alarm Indication Signal Detect: No
FPGA: 00
Log off
Enter
lo
.
RESULT:
The system responds
goodbye
.
end of procedure
Issue
3