Action Steps
Set timing mode
NOTE:
Timing mode applies to all four T1 lines. Loopback mode loops the
T1/E1 Tx clock to the T1/E1 Rx. Recovered mode recovers the T1/E1 clock
from the incoming T1/E1 over Ethernet bit stream (recovers the clock from
the far end T1/E1). The default timing mode is Recovered.
Enter
set clock source [loopback/recovered]
where
[loopback/recovered]
represents the clock timing mode.
RESULT:
The system responds
Clock source is [loopback/recovered]
Set master clock
reference line
NOTE:
This is the master clock reference for all four T1/E1 lines.
The default setting is T1/E1 Port 1.
Enter
set master clock reference line [1/2/3/4]
where
[1/2/3/4]
represents T1/E1 ports 1 through 4.
RESULT:
The system responds
Clk ref line; [1,2,3,4]
Set backup clock
reference line
NOTE:
This is the optional backup clock reference for all four T1/E1 lines.
The backup clock reference becomes active only when the master clock
reference line is unavailable. The default setting is T1/E1 Port 2.
Enter
set secondary clock reference line [1/2/3/4]
where
[1/2/3/4]
represents T1/E1 ports 1 through 4.
RESULT:
The system responds
Backup clk ref line; [1/2/3/4]
Log off
Enter
lo
.
RESULT:
The system responds
goodbye
.
end of procedure