Canopy
T1/E1
Multiplexer
September
2004
T1/E1
Multiplexer
FPGA
Version
3.4
Page
50 of 73
Procedure 18: Configuring E1 line coding using the EMS
Follow these steps to configure line coding from the EMS.
1. From main menu EMS, select the Configuration (
Config
) option.
2. Select
Configure E1
.
RESULT:
The E1 Config dialogue box opens.
3. Click
↓
.
RESULT:
The dropdown list to specify the coding technique E1 channel opens.
4. Click on the appropriate line coding technique for the E1channel being
configured.
NOTE:
You must select a coding technique: either
HDB3
or
AMI
.
5. Click on the tab for the next Channel to configure line coding for channel.
NOTE:
If the system has been reset, clicking the
Refresh
button will replace the
displayed values with currently-programmed values.
6. To configure the line coding technique for each other channel, repeat Steps 3
and 4.
7. Select
Close
to close the dialogue box once all channels are configured.
RESULT:
You are returned to the EMS main menu.
end of procedure
2.5.5
Configure
Ports
Procedure 19: Configuring the Ethernet ports using the EMS
Follow these steps to configure the Ethernet ports using the EMS
1. From the Main Menu, select the pull-down menu
Config
→
Ethernet.
RESULT:
The Ethernet Configuration dialogue box opens.
2. Indicate the appropriate choices by clicking on the appropriate radio buttons.
NOTE:
If you select
Auto Negotiation
Off
, the Ethernet port will be forced to 100
Mbps full duplex.
3. When the Ethernet configuration is complete, click
OK
.
end of procedure
Procedure 20: Configuring the T1 ports using the EMS
Follow this procedure to configure the T1 ports from the EMS.
1. From the pull-down menu, Select
Config
→
T1
.
RESULT:
The T1 Config dialogue box opens.
2. Click
↓
for
Length
.
RESULT:
The dropdown list to specify the cable length for the T1 channel opens.
3. Click on the appropriate line length for the T1 being configured.
NOTE:
An improper length can result in decreased line quality or echo.
Issue