Chapter 3: AT Commands Reference
April 15, 2008
G24-L AT Commands Reference Manual
3-183
+CPWD, Change Password
This command sets a new password for the facility lock. The password can only be changed once
the required facility is enabled by the +CLCK command. (Refer to
“+CLCK, Facility Lock” on
page 3-184
).
A password can be changed only if the provided password <oldpwd> has been verified. The
entered password <newpwd> must also comply to the password rules. The facility value <fac> is
not case-sensitive. In the password value, letters are not allowed.
The following table shows the +CPWD parameters.
Command
Type
Syntax
Response/Action
Remarks
Set
AT+CPWD=<fac>,
<oldpwd>,
<newpwd>
OK
or:
+CME ERROR: <err>
The Set command sets a new password for
the facility lock function, defined by the
+CLCK command. (Refer to
“+CLCK,
Facility Lock” on page 3-184
).
Read
AT+CPWD?
+CME ERROR: <err>
Test
AT+CPWD=?
+CPWD:list of
supported
(<fac>,<pwdlength>)s
OK
or:
+CME ERROR: <err>
The Test command returns a list of pairs
which represent the available facilities, and
the maximum length of their passwords.
Table 3-123: +CPWD Parameters
<Parameter>
Description
<fac>
List of supported facilities. All the facility messages, except for SC and P2, are sent to
the network. (The facilities are not case-sensitive.)
SC
SIM (lock SIM card)
The SIM requests the password during G24-L power-up and when this command is
issued.
AO
BAOC (Bar All Outgoing Calls)
OI
BOIC (Bar Outgoing International Calls)
OX
BOIC-exHC (Bar Outgoing International Calls except to Home Country)
AI
BAIC (Bar All Incoming Calls)
IR
BIC-Roam (Bar Incoming Calls when Roaming outside the home country)
AB
All Barring services (applicable only for <mode>=0)
AG
All outGoing barring services (applicable only for <mode>=0)
AC
All inComing barring services (applicable only for <mode>=0)
P2
SIM PIN2 (
Refer to “+CLCK, Facility Lock”, page 3-184
)
<oldpwd>
String type, 4-8 character password specified for the facility from the G24-L user
interface.
<newpwd>
String type, 4-8 character new password specified by the user.
<pwdlength>
Maximum length of the facility password. Integer type.
Summary of Contents for AT Commands G24-L
Page 4: ......
Page 20: ...List of Tables xvi G24 L AT Commands Reference Manual April 15 2008 ...
Page 56: ...AT Commands Summary 1 26 G24 L AT Commands Reference Manual April 15 2008 ...
Page 402: ...Tools Overview 5 2 G24 L AT Commands Reference Manual April 15 2008 ...
Page 441: ...W W Index April 15 2008 G24 L AT Commands Reference Manual Index 7 ...
Page 442: ......
Page 443: ......