Audio
3-162
G24-L AT Commands Reference Manual
April 15, 2008
The following table shows the S94 parameters.
Example
ATS94=0
//Disable sidetone
OK
ATS94=2
+CME ERROR: <err>
ATS94?
000
//Sidetone disabled
OK
S96, Echo Canceling
This command suppresses a large amount of the output sound picked up by the input device
(cancels all echo). S96 value is saved in the Flex.
The following table explains the use of the ATS96 set.
Table 3-105: S94 Parameters
<Parameter>
Description
<n>
0
Disable sidetone
1
Enable sidetone
On power up the sidetone is enabled.
Table 3-106: ATS96 and ATS94 Behavior
ATS96
ATS94
Echo Cancel
Noise Suppress
ST
0
0
Disabled
Disabled
Disabled
0
1
Disabled
Disabled
Enabled
1
0
Enabled
Enabled
Disabled
1
1
Enabled
Enabled
Disabled
Command Type
Syntax
Response/Action
Remarks
Set
ATS96=<n>
OK
or:
+CME ERROR: <err>
The Set command sets the echo
canceling and noise suppression status.
Read
ATS96?
<000-disabled,
001-enabled>
OK
or:
+CME ERROR: <err>
The Read command returns the echo
canceling and noise suppression status.
Test
ATS96=?
+CME ERROR: <err>
Summary of Contents for AT Commands G24-L
Page 4: ......
Page 20: ...List of Tables xvi G24 L AT Commands Reference Manual April 15 2008 ...
Page 56: ...AT Commands Summary 1 26 G24 L AT Commands Reference Manual April 15 2008 ...
Page 402: ...Tools Overview 5 2 G24 L AT Commands Reference Manual April 15 2008 ...
Page 441: ...W W Index April 15 2008 G24 L AT Commands Reference Manual Index 7 ...
Page 442: ......
Page 443: ......