Hardware Information
3-152
G24-L AT Commands Reference Manual
April 15, 2008
Example
AT+MMAD =1
// Read A2D1 values with analog input of 1.75V.
+MMAD:1,175
OK
AT+MMAD=2,1,15
// Read A2D2 converted value every 15 seconds and send
OK
// unsolicited report to the DTE.
+MMAD: 2, 10
// Unsolicited Report after 15 seconds.
+MMAD: 2, 12
// Unsolicited Report after 30 seconds.
AT+MMAD= 3, 2,1,25,100
// Read A2D3 converted value every 1 second and send
OK
// unsolicited report if the converted value is out of boundaries.
+MMAD: 3,102
// Unsolicited report of value out of boundaries.
:
// Activate Average calcluation periodically every 30 sec, during 5
minutes, rate=5.
// report originated by G24
// Converter num=1, report=3, rate=5*100ms, low,high, N_samples,
duration=5
AT+MMAD =1,3,5, , ,16,5,30
OK
+MMAD:1,175
//First report
+MMAD:1,140
//Second report
…..
+MMAD:1,160
//Last Avr report
AT+MMAD =1,0,5, , ,16,5,0
// Activate Average calcluation during 5 minutes, rate=5.
// Converter num=1, report=0, rate=5*100ms, low,high, 16,
duration=5 min
OK
AT+MMAD=1
//Only on explicit “AT+MMAD=<Converter_number>” command
OK
<Report_interv
al>
0 - 255
Time interval between two averages reports (seconds).
0 - Default value.
<Average>
Average calculation result.
Table 3-98: +MMAD Parameters (Cont.)
<Parameter>
Description
Range/Remark
Summary of Contents for AT Commands G24-L
Page 4: ......
Page 20: ...List of Tables xvi G24 L AT Commands Reference Manual April 15 2008 ...
Page 56: ...AT Commands Summary 1 26 G24 L AT Commands Reference Manual April 15 2008 ...
Page 402: ...Tools Overview 5 2 G24 L AT Commands Reference Manual April 15 2008 ...
Page 441: ...W W Index April 15 2008 G24 L AT Commands Reference Manual Index 7 ...
Page 442: ......
Page 443: ......